Arc Flash and Electrical Safety Best Practices (NFPA 70E 2024)
Learning objectives
- Differentiate between arc flash and electric shock
- Recall hazards, injuries, and indirect consequences related to arc flash and electric shock
- Recognize the way approach protection boundaries are determined
- Match approach boundary criteria with worker qualifications
- Identify necessary training and skills for qualified workers
- Recall primary elements of an electrical safety program
- Recognize the purpose of lock and tag procedures
- Identify different types of lock and tag devices
- Identify basic procedural steps for lock and tag
- Identify the requirements for the use of test instruments and equipment
- Recall the requirements, benefits, and components of a job briefing
- Identify the requirements, benefits, and components of an energized work permit
- Recall PPE responsibilities and requirements related to work around energized electrical equipment and parts
Course overview
What is NFPA 70E (Arc Flash)?
We offer National Fire Protection Association training for electrical safety in the workplace.
For linemen and other utility workers, death by electrocution is a daily hazard that requires attention. In the utility sector, awareness of electrical hazards must be a daily theme for safety and training professionals.
Arc flash and electric shock are both serious electrical hazards, but they differ in their causes and effects.
- An arc flash occurs when a conductive object bridges an energized conductor to the ground or another conductor, resulting in intense heat and light that can vaporize metal. It can happen due to actions like dropping a tool into an electrical panel or due to faulty insulation.
- Electric shock occurs when a person or a conductive object comes into direct contact with an energized electrical component, allowing current to pass through the body to the ground.
The dangers associated with arc flash include severe burns from the heat, eye injuries from ultraviolet and infrared light, hearing damage due to sound pressure from the explosion, and injuries from flying debris.
Electric shock can lead to electrocution, internal tissue and organ damage, and even suffocation. The severity of the injury is influenced by the amount of current and the path it takes through the body.
To reduce the risk of injury in the utility industry, trade associations and federal agencies now have many safe work practices and procedures in place to protect employees when working on or near energized electrical equipment and conductors. Current regulations and industry standards are now in place to protect electrical workers from the hazards of shock, electrocution, arc flash, and arc blast.
The two main regulatory bodies that govern electrical safety in the workplace are the National Fire Protection Association (NFPA) and the Occupational Safety and Health Administration (OSHA). The National Fire Protection Association is recognized for providing information and guidelines that protect workers from electrical hazards, while OSHA is the enforcement agency for electrical safety in the workplace.
Industry Standards Governing Electrical Hazards
- NFPA Standards
- 70-NEC
- 70B Maintenance Electrical
- 70E “Standard for Electrical Safety in the Workplace”
To ensure employees have a safe workplace, your company is required to provide electrical safety training to employees who face a risk of electrical hazards that is not reduced to a safe level by the applicable electrical installation requirements
NFPA 70E (Arc Flash Training) Must Include:
- Specific hazards associated with electrical energy.
- Safe work practices and procedures necessary to provide protection from electrical hazards associated with jobs or tasks.
- Identification of the relationship between electrical hazards and possible injury.
If there is a big, recent change in the way your workforce operates or interacts with electrical equipment or power generation devices, safety professionals have to make changes to protect the workforce, accordingly.
If supervision or annual inspections indicate that employees are not complying with the safety-related work practices, retaining, or refresher training, is then required. Retraining is also required if new technology, equipment types, or changes in processes alter the safe work practices, or if workers must employ safe work practices that are not normally used during regular job duties.
Additionally, for tasks performed less than once a year, retraining is required before employees go back in the field for the performance of related work.
For example, NFPA 70E 110.2 (E) states employers must document that each employee has received the training required for qualified and unqualified employees.
Training Documentation Requirements
- Include employee names and dates of training.
- Be made when the employee demonstrates proficiency in the work practice involved.
- Be maintained for the duration of the employee’s employment.
Electrical tasks that involve working on or near energized electrical equipment or conductors must be performed only by qualified employees, meaning, employees that have received the necessary training required to safely negotiate specific hazards.
A qualified person is defined as one who has the skills and knowledge related to the construction and operation of the electrical equipment and installations and has received safety training to recognize and avoid the electrical hazards that might be present with respect to that equipment or work method. This person has received additional training and demonstrates proficiency in working on exposed energized equipment, recognizing the hazards associated with the task or job, and taking precautions needed to prevent injury or death.
A qualified person will also be trained in the proper use of special precautionary techniques and in selecting and using the appropriate personal protective equipment (PPE)—including arc flash, insulating and shielding materials, and insulated tool and test equipment. Finally, a qualified person must have proper training in responding to emergency situations. That last one is very important but often overlooked.
To be trained as a qualified employee, the employee must actually do the work or have ‘hands on’, performance-based training. Only trained and qualified employees should ever have access to the space within reach of ‘live’ parts or equipment. NFPA 70E (Arc Flash) requires that only trained and qualified employees can work on or near exposed energized electrical parts and supervise unqualified persons in the vicinity of the hazard.
Another requirement of NFPA 70E (Arc Flash) is the implementation of an overall electrical safety program.
NFPA 70E (Arc Flash) Electrical Safety Program Requirements
- Provide awareness training of electrical hazards that includes shock and arc flash.
- Include administrative and engineering controls that measure and monitor methods and procedures for working within the Limited Approach Boundary of energized electrical conductors and circuit parts 50 volts or more.
- Include a hazard and risk evaluation, and job briefing before each job, for repetitive or similar tasks, and for routine work.
- Direct activity appropriate for the voltage, energy level, and circuit conditions.
An Electrical Safety Program must be audited to ensure principles and procedures are being followed. It is important to make sure that your electrical safety program is frequently reviewed, but also measured for performance. The frequency of audits is determined by the employer and based on the complexity of the procedures and the type of work being covered. However, OSHA does require employers to audit their Safety Programs, which include Electrical Safety Programs, at least annually.
- 50 minutes
- Format: Online Interactive
- English
- Introduction
- Arc Flash and Electric Shock
- Making Work Safe
- Elements of an Electrical Safety Program
- The Importance of Best Practices
- Lock and Tag
- Use of Test Equipment
- Job Briefings and Energized Work Permits
- Personal Protective Equipment
- NFPA 70E - Standard for Electrical Safety in the Workplace (2024 Edition)
- OSHA 1910 Subpart I Personal Protective Equipment
- OSHA 1910 Subpart S Electrical
- OSHA 1910.335 - Safeguards for Personnel Protection
- OSHA 1926.28 Personal Protective Equipment